The Factair BA400EX  ZONE 1 are electrically powered, breathing-air compressors designed to operate in a hazardous area (designated Zone I Equipment Group II, category 2 G (IIB T4),
The BA400EX also has a fully integrated automatic fail-safe emergency air reserve and alarm system. In the event a drop in the primary air pressure an audible alarm will be activated and the air will continue be supplied from two 9-litre 200 bar cylinders (optional 300 bar also available). The control panel has a status indicator which in the event of a failure of the primary air will automatically change from green to red. If the air pressure in the HP cylinders drops below 140 bar this will also activate the alarm and status indicator on the control panel.

 

Ask a Question about this product

This product has been discontinued

his product has been discontinued, we recommend you look at the.......

Honeywell Bw Solo

Product Title

Price Available on Request

Please contact Resmar directly to discuss this product and get a personalised quote... thank you

More Information

The BA400EX also has a fully integrated automatic fail-safe emergency air reserve and alarm system. In the event a drop in the primary air pressure an audible alarm will be activated and the air will continue be supplied from two 9-litre 200 bar cylinders (optional 300 bar also available). The control panel has a status indicator which in the event of a failure of the primary air will automatically change from green to red. If the air pressure in the HP cylinders drops below 140 bar this will also activate the alarm and status indicator on the control panel.
They both incorporate a Gardner Denver Hydrovane rotary vane compressor powered by a 5.5kW, 400/480V, 50/60Hz three phase explosion proof electric motor c/w a DOL starter. The compressed air generated is passed through a fan assisted aftercooler before proceeding through a multi-stage filtration system which removes particulates, reduces oil contamination to <0.003 parts per million and also removes hydrocarbon vapours. The air is then passed through a membrane dryer to ensure a 5°C suppression of dewpoint in ambient temperatures >0°C with air quality exceeding the criteria laid down in BS EN12021. Breathing Air is then supplied to 2 flow protected Draeger/Scott compatible outlets.

 

SPECIFICATION
ATEX CLASSIFICATION - Zone 1, Equipment Group II, category 2 G (IIB T4)
MOTOR - Dual voltage input 400V/3PH/50Hz and 460V/3PH/60Hz. ATEX classification II 2 G IIB T4
COMPRESSOR - Hydrovane V04 rotary vane (10 Bar maximum pressure for BA400EX
INTAKE FILTER - Heavy duty complete with adaptor for connecting ducting to provide air from safe area.
AFTERCOOLER - Outlet temperature within 5°C of ambient
FILTRATION - Three stage filtration, comprising pre-filter, coalescing and activated carbon filters.
MEMBRANE DRYER - 5°C suppression of dewpoint in ambient temperatures >0°C
Breathing air quality - conforming to EN 12021. Note: CO and CO2 suppression is not fitted as
                                 standard on these models.
BA OUTPUT CAPACITY -  400 LPM @ 8 Bar
TOTAL CYL. CAPACITY -  On the BA400EX only emergency reserve air supply is provided in high pressure cylinders
                                     that must be refilled elsewhere. The unit cannot be operated without these cylinders in
                                     place, at a pressure above the minimum safe condition and they must be turned on while
                                     the compressor is in use. Cylinder alternatives are:-
                                     2 off 9 litre 200bar HP cylinders, 3,600 litres storage capacity.
                                    or 2 off 9 litre 300 bar HP cylinders, 5,400 litres storage capacity
CHASSIS - Heavy duty includes conductive wheels and earth connection point.
DIMENSIONS - Length 1340mm, Width 720mm, Height 935mm Weight 300Kg - BA400EX, 270Kg – BA500EX
STANDARD FEATURES - Over temperature protection, automatic ‘fail-safe' reserve from high pressure cylinders with
                                    start up warning
CONTROL PANEL - Gauges Compressor Pressure, Outlet Pressure, HP Cylinder Pressure (BA400EX only)
Status Indicators – Red/Green Visual Changeover
OUTLETS - 2 off Draeger/Scott compatible couplings for positive pressure devices. Alternative constant
                flow compatible outlets available.
AUDIBLE ALARMS - Primary air supply failure. - Air reserve inadequate (BA400EX only)
                             NOISE LEVEL <71 LWA.
WASTES - Discharge from condensate autodrains gathered into a container for proper disposal


Air QUALITY are manufactured in accordance with our Quality Assurance Procedures
approved to ISO9001.

Resmar 35 Years Logo

Supporting businesses just like yours for more than 35 years

Contact us and see how we can support your business

C2A Contact Form

Safety Equipment Servicing

Our service and maintenance staff are there for you 24/7

Find out more

Safety Equipment Hire

Our sister company Able Safety offer safety equipment hire

Find out more

What our Clients Say

Se Servicing Block

We been dealing with Resmar for over 25 years. They are always at the end of the phone ready to help, it doesn’t matter what time of day or night. I know we can call and get person on the end of the line and not an answering machine. From their sales team to their Engineers, we get a first class service.

Paul Jameson

QSHE Manager - GXO

Testimonial 1

Don at Resmar, knows his stuff and can deliver next day. Experienced and knowledgeable.

Ashley Taylor

aerial photography of tanker ship

We love dealing with Resmar as they can always help when there is an issue. Our ship needed a repair of some gas monitors in Immingham. We called on a Friday afternoon and an engineer was there that night. A couple of hours later we were all fixed and ready to leave at high tide with our calibration certificate.

Davied Morris

Chief Engineer